200 mg Precision Calibration Weight Platter Stainless Steel Polished, OIML F2 ±0.2 mg - KERN
€10.00
Product information "200 mg Precision Calibration Weight Platter Stainless Steel Polished, OIML F2 ±0.2 mg - KERN"
Combining OIML Class F2 accuracy with a polished stainless steel disc and a nominal value of 200 mg, this milligram standard provides dependable calibration performance for sensitive balances; order the item directly via Metav Werkzeuge or ask our consultants if needed.
KERN 338-08 Milligram weight — 200 mg, OIML F2, polished stainless-steel disc
The KERN 338-08 is a polished stainless-steel milligram weight in disc form, designed for precise calibration tasks with analytical balances and micro-scales in laboratories and quality-control environments.
- OIML Class F2 accuracy, 0.2 mg tolerance
- Polished stainless-steel disc design
- Nominal value: 200 mg, milligram weight
- Suitable for analytical balances and micro-scales
Precision where it matters for calibration reliability
The KERN 338-08 is specified to OIML Class F2, making it appropriate for high-precision checking and calibration tasks where small deviations must be controlled. With a nominal value of 200 mg and a declared tolerance of 0.2 mg, the standard offers a narrow uncertainty band that supports repeatable results when verifying instruments with fine readability. For teams seeking measurable process control, the combination of classification and tight tolerance reduces uncertainty in routine checks and certificate-based comparisons.
Robust material and disc geometry for handling and stability
Manufactured from polished stainless steel, the weight provides corrosion resistance and a surface finish that helps maintain mass stability over time. The disc form minimises handling errors when used with tweezers or picking tools and fits common balance pans used in laboratory practice. The material choice ensures that routine cleaning and handling do not accelerate surface wear, supporting longer intervals between recalibrations and preserving the visible condition required for traceable standards.
Fits into formal calibration workflows and traceability
To meet traceability requirements, a DAkkS calibration is recommended; a formal DAkkS calibration produces a certificate suitable for many official and contractual applications. Note that EC initial verification of weights will no longer be possible from 30 November 2025, which makes accredited laboratory calibration the preferred route for documented conformity. Given the milligram class and sensitivity, a protective case is advised to prevent contamination and mechanical damage during storage and transport.
Confidence through supply and expertise from Metav
Metav’s approach of combining accessible precision with professional supply ensures reliable availability and a quality filter from its Emmerich location. Backed by a large product range and a longstanding customer base, the offering supports workshop and laboratory needs with consistent logistics and documentation. For users who value dependable calibration items and a supplier that matches technical competence with practical service, this milligram standard integrates into established quality-management procedures.
Contact Metav Werkzeuge in Emmerich for personalised advice, DAkkS calibration options and assisted ordering for the KERN 338-08 milligram weight
Technical data
- Article number: T338-A
- SKU: 338-08
- Manufacturer: KERN
- GTIN: 4045761240292
- Origin: CN
Core data
- Nominal value: 200 mg
- Tolerance (OIML F2): 0.2 mg
- OIML class: F2
- Tariff code: 84239090
Special features
- Material: Stainless steel
- Form: Disc
- Recommended accessory: protective case (etui)
- Calibration: DAkkS calibration recommended
- Note: EC initial verification not possible from 30 November 2025
FAQ
What applications suit an OIML Class F2 milligram weight?
OIML Class F2 weights like the KERN 338-08 are suited to calibration and routine checks of analytical balances and micro-scales where milligram-level control is required.
Is a calibration certificate available for this weight?
Yes; for traceable documentation a DAkkS calibration can be organised for the KERN 338-08, which provides an accredited certificate suitable for most quality-management systems.
Why is a protective case recommended?
Because of the very fine tolerance of 0.2 mg, contamination or surface damage affects performance; a protective case preserves mass integrity and extends the interval between recalibrations.
Can this weight be used after 30 November 2025 for official EC initial verification?
EC initial verification of weights will no longer be possible from 30 November 2025; the recommended route for documented conformity for the KERN 338-08 is an accredited laboratory calibration such as DAkkS.
How should the weight be handled to maintain accuracy?
Handle the disc with tweezers or gloves, avoid fingerprints and dust, store it in the recommended protective case and follow a regular calibration schedule to maintain the declared tolerance.
KERN — Manufacturer; Metav Werkzeuge, Emmerich am Rhein; Email: info@metav-werkzeuge.com; Phone: +49 2822 7131930