Skip to main content Skip to search Skip to main navigation
Cheap Shipping Cost
fast shipment
Advice before purchase
Purchase comfortable on account
Hotline +49 2822 7131930

Reliable Modbus transmission for measurement systems

This Modbus transmission solution converts USB‑C outputs from precision measuring instruments into field‑ready Modbus RTU signals, enabling direct connection to PLCs and SCADA systems and reducing manual data handling. The compact industrial gateway provides a deterministic serial bridge with configurable baud rates (default 9600 bps) for predictable communication and faster commissioning, making it ideal for integrating laboratory‑grade DataMet devices into process control. Rated for typical inspection bench conditions, the IP40 enclosure and operation from 5–40 °C support continuous shop‑floor use while extending the value of existing instrument fleets through seamless system integration and protocol compatibility.

Filter products

53x82x31 mm Modbus RTU Data Box IP40, RS‑485 Microtech Metrology

53x82x31 mm Modbus RTU Data Box IP40, RS‑485 Microtech Metrology

Compact industrial gateway converts USB‑C metrology outputs to Modbus RTU over RS‑485, with configurable serial settings and an IP40 enclosure — ideal for integrating laboratory-grade measuring instruments into process control. Benefit from reliable protocol compatibility and a small footprint; order the module directly via Metav Werkzeuge or consult the Metav specialists for integration advice. Modbus RTU Data Box (Microtech Metrology) — RS‑485 gateway for DataMet instruments The Modbus RTU Data Box links Microtech DataMet instruments to industrial controllers and SCADA environments, providing a robust serial bridge for continuous data transfer and machine‑level integration. Modbus RTU protocol for industrial integration RS‑485 4‑wire interface (A, B, GND, 5–24 V) Compact IP40 enclosure, 53 × 82 × 31 mm Seamless system integration for process control This Modbus RTU interface simplifies the transfer of measurement values from laboratory instruments into automation systems, enabling direct connection to PLCs and data loggers via RS‑485. With a hardwareised serial bridge designed for deterministic communication, commissioning time is reduced: the default 9600 bps setting offers immediate compatibility with many legacy systems while the configurable baud rate ensures adaptation to faster networks. The result is a predictable, industrial‑grade data path that supports traceable processes and reduces manual transcription. Small footprint, industrial robustness Housed in a compact enclosure of 53 × 82 × 31 mm, the unit occupies minimal panel space while delivering the mechanical stability required for measurement setups. The IP40 rating and specified operating range keep the interface suitable for indoor workshop and laboratory environments where protection against coarse particles and controlled humidity is sufficient. The lightweight construction (approx. 0.15 kg) aids neat mounting and tidy cable routing without adding bulk to measurement stations. Clear serial parameters for dependable transfers Serial communications are framed to industry norms: default 9600 bps, 8 data bits, 1 stop bit and no parity, which together provide a standardised data format that simplifies protocol stacks on PLCs and SCADA systems. Clear, documented settings reduce ambiguity during integration and help maintain data integrity across longer RS‑485 bus runs. The four‑wire RS‑485 connection (power line plus A/B pair and ground) supports stable signalling for multi‑drop topologies. Built to fit metrology workflows Designed specifically for use with Microtech measurement equipment, the module accepts USB‑C input from DataMet instruments and converts that stream into a field‑ready Modbus RTU signal. The unit is supplied without a measuring tool and therefore complements existing instrument fleets rather than replacing them. Rated for operation between 5–40 °C and up to 70 % relative humidity, the interface is tailored to the ambient conditions typical of inspection benches and machine shops, helping to extend the utility of precision instruments into live production monitoring. Discuss integration and delivery options with Metav Werkzeuge — our specialists can advise on wiring, protocol mapping and compatibility for Microtech installations; eMail info@metav-werkzeuge.com or call +49 2822 7131930 Technical Data Article number: 141077071 Label: Modbus RTU data box Type: Modbus RTU data box Manufacturer: Microtech Metrology Facts Dimensions: 53 × 82 × 31 mm Weight: 0.15 kg Working temperature: 5–40 °C Humidity: up to 70 % Water protection: IP40 Default baud rate: 9600 bps (configurable) Data bits: 8 Stop bits: 1 Parity: None Special features Protocol: Modbus RTU Interface: RS‑485, 4‑wire (5–24 V, GND, A, B) Connection to Microtech DataMet instruments via USB‑C Delivery without measuring tool Designed for integration into PLC/SCADA systems FAQ Is Modbus RTU the only supported protocol? The Modbus RTU data box from Microtech Metrology supports the Modbus RTU protocol for industrial integration; it is designed specifically to provide a Modbus RTU output from compatible DataMet instruments (SKU 141077071). Can the module be connected directly to a PLC RS‑485 port? Yes; the device provides a four‑wire RS‑485 interface (A, B, GND, and a 5–24 V supply line) for direct connection to PLC fieldbus ports or RS‑485 gateways using standard cabling. Is the unit suitable for outdoor use or wet environments? No; the enclosure is rated IP40, which protects against solid objects but is not intended for wet or outdoor locations. The product is intended for controlled indoor environments. Are the serial settings changeable on site? Yes; the default 9600 bps can be reconfigured where required, and standard framing parameters (8 data bits, 1 stop bit, no parity) are provided to ensure compatibility with most automation systems. Does the delivery include a measuring instrument or calibration certificate? The Modbus RTU data box is supplied without a measuring tool; it operates as an interface for Microtech DataMet instruments and does not include calibration documentation for measuring devices. Manufacturer / Responsible: Microtech, Nizhneyurkovska str., 45a, 04080 Kyiv, Ukraine, tool@microtech.tools

Regular price: €330.00
Product Quantity: Enter the desired amount or use the buttons to increase or decrease the quantity.

53x82x31mm Modbus RTU Data Box With RS-485 Output, IP40 - Microtech Metrology

Integrate reliable Modbus RTU connectivity with compact IP40 protection and configurable serial settings for direct industrial connection; order this interface module directly via Metav Werkzeuge or request technical advice from our consultants. Modbus ASCII data box — Industrial Modbus RTU gateway with RS‑485 and USB‑C The Modbus ASCII data box offers a compact interface for connecting Microtech DataMet instruments to industrial networks, converting USB‑C output to a stable RS‑485 Modbus RTU link for data acquisition and process control. MODBUS RTU output via RS‑485 4‑wire USB‑C connection for Microtech DataMet instruments Configurable 9600 bps baud rate Compact IP40 enclosure 53×82×31 mm Seamless industrial data integration for measurement systems This compact industrial gateway translates instrument output into Modbus RTU, providing deterministic serial communication for PLCs, SCADA systems and data loggers. By offering an RS‑485 4‑wire interface it preserves signal integrity over long cable runs, while the USB‑C link keeps the connection simple for Microtech DataMet devices. The predictable transfer characteristics, including a default 9600 bps rate, reduce integration time and support automated logging and quality control routines, so measurement data can be consumed directly by production systems without custom converters. Reliable operation within standard workshop environments Engineered for everyday industrial conditions, the unit operates between 5–40 °C and up to 70% relative humidity, with an IP40 enclosure that protects against solid ingress in guarded installations. The small footprint ( 53×82×31 mm ) and low mass ( 0.15 kg ) ease panel or enclosure placement where space is at a premium. Supplied without a measuring instrument, the module is intended as a communications accessory to augment existing metrology hardware rather than a standalone gauge, simplifying inventory and allowing the integration of certified instruments already in use. Simple serial configuration and robust protocol support Configuration follows established serial conventions: 8 data bits, 1 stop bit, and no parity, with the baud rate configurable (default 9600 bps) to match existing field devices. The RS‑485 interface accepts the common 4‑wire wiring (5–24 V, GND, A, B), enabling straightforward connection to industrial masters. These well‑known settings minimise engineering adjustments and ensure reliable cyclic polling or event‑driven reporting, which helps maintain measurement traceability and reduces the risk of communication errors during production runs. Suited to metrology workflows and automated data collection As a purpose‑built interface for Microtech instruments, the module supports streamlined data capture and archival in quality systems and MES layers. Its compact design and standardised protocol support lower cabling complexity and make it easier to centralise readings from distributed gauges. For facilities seeking to digitise routine inspection and monitoring tasks, the device provides a practical, low‑effort route to feed laboratory‑grade measurements into control and reporting stacks, improving process transparency and decision reliability. For tailored advice on integrating Microtech instruments via this Modbus gateway, contact Metav Werkzeuge for compatibility checks and ordering from our Emmerich stock; email info@metav-werkzeuge.com or call +49 2822 7131930 Technical data Article number: 141077072 Type: Modbus ASCII data box Protocol: Modbus RTU Device compatibility: Microtech DataMet instruments (USB‑C) Delivery: without measuring instrument Numeric data Working temperature: 5–40 °C Humidity: 70% IP rating: IP40 Baud rate: 9600 bps (configurable) Data bits: 8 Stop bits: 1 Dimensions: 53×82×31 mm Weight: 0.15 kg Features & connections RS‑485 4‑wire connection (5–24 V, GND, A, B) USB‑C interface for instrument connection Modbus RTU protocol support Compact enclosure for panel or enclosure integration FAQ Is this data box compatible with Microtech DataMet instruments? Yes. The Modbus ASCII data box is designed to interface with Microtech DataMet instruments via USB‑C and to present their output as Modbus RTU over RS‑485 (SKU 141077072). What are the operating limits for temperature and humidity? The module is specified to operate between 5–40 °C and up to 70% relative humidity, with IP40 protection for typical workshop and industrial environments. Can the communication speed be adapted to existing systems? The device uses a configurable baud rate with a default of 9600 bps; serial settings include 8 data bits, 1 stop bit and no parity to match common industrial masters. What wiring is required for the RS‑485 connection? Wiring follows a 4‑wire RS‑485 scheme (power range 5–24 V, GND, A, B) to ensure robust differential signalling for industrial distances. Is a measuring instrument included with delivery? No. Delivery is without a measuring instrument; the data box is an interface accessory intended to connect with existing Microtech measurement devices. Manufacturer / Responsible: Microtech, Nizhneyurkovska str., 45a, 04080 Kyiv, Ukraine, tool@microtech.tools

Regular price: €399.00
Product Quantity: Enter the desired amount or use the buttons to increase or decrease the quantity.
Modbus TCP/IP Data Box For Microtech DataMet Instruments RS‑485 IP40 - Microtech Metrology

Modbus TCP/IP Data Box For Microtech DataMet Instruments RS‑485 IP40 - Microtech Metrology

Take advantage of a compact interface that converts USB‑C instrument output into an industrial Modbus RTU stream combined with a RS‑485 4‑wire connection and configurable serial settings for straightforward system integration; its IP40 enclosure and small footprint keep installation simple in controlled environments. Order the Modbus TCP/IP data box directly via Metav Werkzeuge or ask our consultants if needed. Modbus TCP/IP Data Box — Modbus RTU gateway with RS‑485 and USB‑C for Microtech instruments Modbus TCP/IP Data Box provides a compact gateway to integrate Microtech DataMet instruments into industrial Modbus networks, converting USB‑C output into a configurable RS‑485 Modbus RTU interface for data collection and automation tasks Industrial Modbus RTU interface (RS‑485) Compact IP40 housing, 53×82×31 mm Configurable baud rate, default 9600 bps USB‑C compatibility with DataMet instruments Reliable serial integration for automation and data logging The device converts a USB‑C output from measurement instruments into a standardised Modbus RTU protocol over RS‑485, enabling direct connection to PLCs, data loggers and SCADA systems. With a configurable baud rate (default 9600 bps) and fixed settings of 8 data bits, 1 stop bit and no parity, the unit simplifies serial configuration and reduces commissioning time. This stability ensures consistent data transfer for production monitoring and traceability. Small footprint, robust connection in controlled workshops Housed in an IP40 enclosure and measuring 53×82×31 mm, the unit is designed for neat mounting near measurement stations where protection from large particles and light contact is sufficient. The compact dimensions and low weight make it easy to integrate into instrument racks or control cabinets without requiring additional space. The modest protection class suits many indoor industrial and laboratory settings while keeping wiring runs short. Clear operating window and environmental limits for dependable operation Rated for operation between 5–40 °C with up to 70% humidity, the interface is intended for typical workshop and laboratory conditions rather than harsh outdoor environments. Specifying these environmental limits helps planners choose appropriate locations and enclosures so the interface maintains reliable communications and long service life. The device is supplied without a measuring instrument and is intended to be paired with Microtech DataMet series equipment. Practical protocol and wiring details explained The RS‑485 output is a four‑wire arrangement (5–24 V, GND, A, B) commonly used for industrial Modbus RTU networks; this ensures galvanic reference and signal integrity across longer cable runs. Explaining the wiring and protocol behaviour reduces installation errors and supports predictable system behaviour during commissioning. The gateway converts USB‑C instrument data to a widely supported field protocol, enabling legacy systems and modern controllers to share measurement values without bespoke drivers. For straightforward Modbus RTU integration with Microtech instruments, contact Metav Werkzeuge for ordering or to request a technical consultation on network wiring and configuration; Metav Werkzeuge provides local support from Emmerich and can advise on matching the gateway to existing control systems. Technical Data Article number: 141077073 Type: Modbus TCP/IP data box Protocol: Modbus RTU Connection: USB‑C (instrument side) / RS‑485 4‑wire (5–24 V, GND, A, B) Delivery: without measuring instrument Facts Working temperature: 5–40 °C Humidity: 70% Protection class: IP40 Dimensions: 53×82×31 mm Weight: 0.15 kg Baud rate: 9600 bps (configurable) Data bits: 8 Stop bits: 1 Parity: None Special features Designed for integration with Microtech DataMet instruments Converts USB‑C output to Modbus RTU over RS‑485 Compact enclosure for instrument racks and control cabinets Configurable serial settings for compatibility with PLCs and SCADA FAQ What does the gateway do in a measurement setup? The Modbus TCP/IP data box converts USB‑C output from a Microtech DataMet instrument into a Modbus RTU stream on RS‑485, allowing PLCs and data loggers to read measurement values directly. Which serial settings are used by default and can they be changed? Default serial settings are 9600 bps, 8 data bits, 1 stop bit, no parity; the baud rate is configurable to match the host system. Is the device suitable for outdoor or wash‑down environments? No; the unit has IP40 protection and is intended for indoor workshop or laboratory use within the stated 5–40 °C and 70% humidity range. Does the product include the measuring instrument or calibration certificate? The delivery is without a measuring instrument; calibration certificates are not included with the data box unless explicitly stated for the paired instrument. What wiring is required to connect to a PLC? A four‑wire RS‑485 connection (5–24 V, GND, A, B) is required; the gateway appears on the Modbus network as a standard RTU device for polling. Manufacturer / Responsible: Microtech, Nizhneyurkovska str., 45a, 04080 Kyiv, Ukraine, tool@microtech.tools

Regular price: €550.00
Product Quantity: Enter the desired amount or use the buttons to increase or decrease the quantity.

Integrate laboratory measurement into process control

A compact solution for modbus transmission, the Modbus RTU Data Box converts USB‑C metrology outputs from Microtech DataMet instruments into industry‑ready Modbus RTU signals. Designed for a small footprint and reliable protocol compatibility, the unit links laboratory‑grade measuring tools to PLCs, SCADA systems and data loggers without replacing existing instruments.

How modbus transmission performs in live production

The device operates as a hardwareised serial bridge that provides deterministic communication between measurement devices and controllers. Modbus is a proven, open communication protocol that follows a master–slave (client–server) model: a central controller (the master, e.g. a plc or pc) polls connected field devices (slaves, such as sensors or measurement tools) and receives responses only when addressed. Communication can take place serially via Modbus RTU or over networks via Modbus TCP, and the Data Box is geared towards Modbus RTU for direct serial integration.

Built for metrology workflows and shopfloor conditions

  • accepts USB‑C input from DataMet instruments and outputs a field‑ready Modbus RTU stream.
  • default 9600 bps setting for immediate compatibility with legacy systems; configurable baud rate for faster networks.
  • rated for operation at 5–40 °C and up to 70% relative humidity, matching inspection bench and machine shop environments.
  • housed in an IP40 enclosure with a compact footprint suitable for integration near workstations.
  • hardwareised serial bridge reduces commissioning time and supports traceable, predictable data transfer.

Why choose Metav for integration and support

Metav combines specialist know‑how with a broad offering that makes industrial integration straightforward. As a precision partner, Metav enables democratisation of accurate measurement by supplying compatible interfaces and by advising on implementation. With over 48,000 customers, a stock of more than 250,000 products and a logistics hub in Emmerich, Metav provides dependable supply and practical integration guidance for modbus transmission projects. For specialist needs, Metav’s technicians can advise on selecting the right modbus gateway or serial modbus interface for your measurement fleet.

Summary

The Modbus RTU Data Box extends the reach of existing measurement instruments into process control by converting USB‑C outputs into robust modbus transmission streams. Its deterministic bridge, configurable serial settings and shopfloor rating make it a practical choice for continuous monitoring and automation.

FAQ

What exactly is a modbus transmission interface and when is it used?
A modbus transmission interface converts measurement outputs into the Modbus protocol so values from instruments such as Microtech DataMet devices can be polled by PLCs, scada systems or data loggers for process control and monitoring.

Does the device support legacy systems out of the box?
Yes. The unit ships with a 9600 bps default setting to ensure immediate compatibility with many legacy serial installations, while the configurable baud rate allows adaptation to modern communication requirements.

Can the interface operate in a typical workshop environment?
The device is specified for operation between 5–40 °C and up to 70% relative humidity and is supplied in an IP40 enclosure, making it suitable for inspection benches and many machine shop conditions.

Which product name should I search for when looking for this type of solution?
Search for modbus transmission devices, serial modbus interfaces or modbus gateways compatible with Microtech DataMet instruments; these terms reflect the corrected category and common synonyms used in industrial procurement.

Fragen zu diesen Produkten??

Mit mehr als 30 Jahren Erfahrung beraten wir Sie gerne persönlich.

Tel.: +49 2822 7131930

Mail: info@metav-werkzeuge.com