Skip to main content Skip to search Skip to main navigation
Cheap Shipping Cost
fast shipment
Advice before purchase
Purchase comfortable on account
Hotline +49 2822 7131930
Mikroskop, Binokularmikroskop, Weißes Gehäuse, Drehtisch, Objektivrevolver

Filter products

Euromex λ/4 Platte im Schieber für Durchlichtbeleuchtung für iScope-Polarisationsmodelle IS.9612., Metallplatte, Aperturöffnung, Schwarz, Optisches Bauteil, Markierungen

λ/4 Plate Slide for Transmitted Illumination Polarisation Models, IS.9612 - Euromex

Combining precise quarter-wave retardation with a quick-action slider, this accessory delivers reliable polarisation control for transmitted-light microscopy, ideal for contrast enhancement and workflow efficiency. Order the Euromex IS.9612 directly via Metav Werkzeuge or request advice from our consultants. λ/4 Plate in Slider for Transmitted-Light Illumination — iScope Polarisation Accessory (Euromex IS.9612) The λ/4 plate in slider for transmitted-light illumination for iScope polarisation models IS.9612 is an optical accessory enabling controlled retardation for polarisation contrast in transmitted-light microscopy. Quarter-wave retardation plate for polarisation contrast Compact slider mount for rapid insertion and removal Compatible with iScope polarisation series Designed to improve transmitted-light imaging consistency Enhanced contrast and controlled retardation for clearer imaging The accessory uses a quarter-wave plate (λ/4) to transform linear into circular polarisation or to introduce a defined phase shift between orthogonal polarisation components. This retardation reduces interference effects and improves visibility of birefringent structures in transmitted-light applications. For laboratory technicians and quality-control staff, the technical advantage is straightforward: better contrast with minimal modifications to the optical path. The slider design allows the optical element to be introduced without dismounting condenser assemblies, preserving alignment and saving time during routine inspections. Workflow advantage from the slider mechanism Fitting the plate in a slider mount provides immediate operational benefits: the element can be engaged or removed in seconds, which supports rapid switching between polarised and non-polarised transmitted-light modes. In production or classroom environments where throughput matters, this accessory reduces downtime and simplifies sample handling. The compact form factor integrates with iScope polarisation units and maintains a consistent optical position, so measurement reproducibility and imaging consistency are supported without complex recalibration. Built for dependable optical performance in microscopy tasks Manufactured to support polarisation contrast methods, the component contributes to repeatable imaging results across microscopy workflows. Its role in transmitted-light polarisation enhances the detection of stress patterns, crystalline structures and fine textural detail in materials and biological specimens. The accessory is therefore suited to research laboratories, industrial inspection benches and educational settings seeking improved visual differentiation of anisotropic features. For further specification details or to verify compatibility with a specific iScope variant, technical consultation is available. Secure the Euromex IS.9612 via Metav Werkzeuge for precise polarisation control and seamless integration into iScope setups; contact Metav Werkzeuge for tailored specification advice at info@metav-werkzeuge.com or call +49 2822 7131930 Technical Data Article number: IS.9612 SKU: IS.9612 Brand: Euromex Product type: Microscope illumination accessory Facts File size: 37693 Gallery filename: IS.9612.jpg Category path: Microscopy accessories › Contrast methods › Polarisation Special features Quarter-wave plate (λ/4) in slider for transmitted-light illumination Designed for iScope polarisation models Application: polarisation contrast in transmitted-light microscopy FAQ What is the primary function of the λ/4 plate in this accessory? The λ/4 plate in the Euromex IS.9612 introduces a defined phase retardation to enhance polarisation contrast in transmitted-light microscopy, improving visibility of birefringent details. Which microscope series is this slider designed for? The slider is designed for iScope polarisation models and fits the corresponding transmitted-light illumination path of that series. Can the plate be inserted and removed without realigning the microscope? Yes, the slider mount allows rapid insertion and removal with minimal disturbance to the optical alignment, supporting consistent imaging across sessions. What types of samples benefit most from using this polarisation accessory? Samples exhibiting birefringence—such as crystalline materials, polymers, or stressed transparent components—benefit substantially, as do biological specimens where polarisation reveals structural detail. Is additional calibration required after introducing the plate? Basic checks are recommended, but the slider is designed to maintain optical positioning so extensive recalibration is usually unnecessary. Manufacturer / Responsible: Metav Werkzeuge GmbH; Parkring 45; 46446 Emmerich; Germany; +49 2822 7131930; info@metav-werkzeuge.com

Regular price: €185.00
Product Quantity: Enter the desired amount or use the buttons to increase or decrease the quantity.

λ/4 Plate Slider for Incident Light Illumination Polarisation Models, IS.9612-R - Euromex

Take advantage of precise polarisation control and space-saving integration to enhance reflected-light inspections; the compact slider design ensures quick insertion and repeatable positioning while maintaining optical performance. Order the accessory directly via Metav Werkzeuge or ask our consultants for application advice. Quarter-wave plate slider for reflected-light polarisation — Euromex IS.9612-R The Quarter-wave plate slider IS.9612-R is a precision accessory for polarisation microscopy, designed to introduce adjustable retardation in reflected-light illumination for iScope polarisation models. Quarter-wave plate in slider format For reflected-light illumination Compatible with iScope polarisation models Manufacturer: Euromex, SKU IS.9612-R Improved contrast and polarisation control for reflected-light work A quarter-wave plate (λ/4 plate) is an optical retarder that shifts the phase between orthogonal polarisation components; this converts linearly polarised light into circular polarisation or adjusts the ellipticity of the beam. In reflected-light microscopy, that phase shift can be used to enhance contrast and reveal surface stress or birefringence effects that would otherwise remain hidden. The slider-mounted design permits quick changeover and consistent optical alignment, ensuring that the retardation effect is reproducible from one specimen to the next. Slider format that speeds up routine inspection The slider mechanism integrates the retarder element into standard filter housings or illumination carriers used in polarisation setups, enabling immediate insertion and removal without additional tools. This format supports efficient workflows in production control and research labs where time and repeatability matter. By combining compact physical integration with stable optical positioning, the slider reduces handling time and minimises the chance of misalignment, delivering repeatable positioning and improved throughput during microscope-based inspections. Designed for iScope polarisation systems and reflected-light applications This accessory has been developed for compatibility with iScope polarisation models, matching the mechanical and optical interfaces commonly used in those systems. The element is intended specifically for reflected-light illumination, so it is best suited to surface analysis, metallography and materials inspection tasks where polarisation effects on reflected beams are exploited. The manufactured build and optical finish support consistent results in routine laboratory and quality-assurance environments. Practical benefits for laboratories and technical inspection Choosing a dedicated quarter-wave slider enables targeted enhancement of imaging contrast with minimal modification to existing equipment. Laboratories benefit from a compact, purpose-built optical element that fits into established polarising workflows, offering a clear technical upgrade without the need for extensive reconfiguration. For teams assessing surface features, stress patterns or anisotropic coatings, the component provides a reliable method to make those characteristics more visible under polarisation conditions. For precise polarisation upgrades, order the Euromex quarter-wave plate slider via Metav Werkzeuge or contact our technical consultants at info@metav-werkzeuge.com or +49 2822 7131930 to confirm fit and application details. Technical Data Manufacturer article number: IS.9612-R SKU: IS.9612-R Manufacturer: Euromex Product type: microscope illumination Facts No detailed numerical specifications provided Special features Quarter-wave plate in slider for reflected-light illumination Compatible with iScope polarisation models Category path: Polarisation (microscopy accessory) Image: IS.9612-R.jpg — https://plytix-files.com/api/v1.1/file/public_files/pim/assets/57/c3/98/62/6298c3575d155f1bc7e497fd/images/1d/a5/f1/6a/6af1a51dd8ecf2f60acae091/IS.9612-R.jpg FAQ What does a quarter-wave plate do in reflected-light microscopy? A quarter-wave plate introduces a phase shift between orthogonal polarisation components; in reflected-light applications the IS.9612-R from Euromex alters polarisation states to enhance contrast and reveal birefringent or stress-related features on surfaces. Is this slider compatible with iScope polarisation models? Yes — the slider is designed for use with iScope polarisation models and fits common reflected-light filter housings used in those systems. Can the quarter-wave slider be used for transmitted-light polarisation? The IS.9612-R is specified for reflected-light illumination; for transmitted-light polarisation applications, check the system requirements and seek a retarder specified for transmitted-light use. How does the slider format benefit routine inspections? The slider format enables rapid insertion and removal with stable optical alignment, delivering repeatable positioning and reduced handling time during inspection processes. Manufacturer: Euromex; Responsible: Metav Werkzeuge GmbH; Parkring 45; 46446 Emmerich; Germany; +49 2822 7131930; info@metav-werkzeuge.com

Regular price: €185.00
Product Quantity: Enter the desired amount or use the buttons to increase or decrease the quantity.

Fragen zu diesen Produkten??

Mit mehr als 30 Jahren Erfahrung beraten wir Sie gerne persönlich.

Tel.: +49 2822 7131930

Mail: info@metav-werkzeuge.com